学科分类
/ 4
74 个结果
  • 简介:摘要目的探讨3.0T磁共振波谱成像(1H-MRS)、动态增强扫描(DCE-MRI)及其联合应用对乳腺癌的诊断价值.方法我院2013年3月至2015年8月磁共振资料完整并经穿刺活检或手术病理证实的乳腺肿瘤患者123例,其中乳腺恶性肿瘤67例,良性肿瘤56例,回顾分析所有氢质子波谱及动态增强扫描数据,与病理结果对照,比较单独使用1H-MRS、DCE-MRI以及二者联合应用诊断乳腺癌的敏感性、特异性及诊断准确率.数据采用X2检验统计分析.结果单独以动态增强扫描的时间-信号强度曲线类型单独诊断乳腺癌的敏感性为83.58%,特异性为62.50%,准确率为73.98%;单独应用1H-MRS,以是否出现胆碱峰(Cho)来诊断乳腺癌的敏感性为52.24%,特异性为87.50%,准确率为68.29%;DCE-MRI联合1H-MRS诊断乳腺癌的敏感性为95.52%,特异性为91.07%,准确率为93.50%.结论单独应用DCE-MRI诊断乳腺癌的敏感性高,但特异性相对较低,良恶性病变表现之间存在重叠;单独应用1H-MRS特异性较高,但敏感性相对较低;二者联合应用可提高诊断敏感性、特异性及准确率.关键词磁共振成像;动态增强;磁共振波谱Thevalueof1H-MRSandDCE-MRIcombinedapplicationinthediagnosisofbreastcancerLiZhen1,ZouYue-fen1,WangXiao-hui2,ZhenXiao-feng2(1.Thefirstaffiliatedhospitalofnanjingmedicaluniversity,nanjing,jiangsuprovince,210029;2.Beijingaerospacegeneralhospitalimagecenter,BeiGjing100076)AbstractObjectiveTostudythevalueof3.0TMagneticResonanceSpectroscopy,(1H-MRS)、DynamicContrast-EnhancedMRI(DCE-MRI),anditscombinedapplicationindiagnosisofbreastcancer.Methods123casesbreasttumors(67malignantand56benigntumor)werecollected,whichwereconfirmedbypathologicalafterbiopsyorsurgical.Allpatientsundergoingroutinescan,DCE-MRIafterinjectionofcontrastagentand1H-MRSexamination,TimesignalIntensityCurve(TIC)typeandpresenceofabnormalincreaseofcholinepeak(Cho)wereanalyzed,comparedwiththepathologicalresults.usingX2-testasstaGtisticalmethods,computationaldiagnosticsensitivity,specificityanddiagnosticaccuracyofbreastcancer.ResultsDiagnosisbreastcancerwithTICtype,thesenGsitivitywas83.58%,specificitywas62.50%,theaccuracywas73.98%.With1H-MRS,thesensitivitywas52.24%,specificitywas87.50%,theaccuracywas68.29%.withDCE-MRIjoint1H-MRS,thesensitivitywas95.52%,specificitywas91.07%,theaccuracywas93.50%.ConclusionApplicationofsignalDCE-MRI,thesensitivityishigherinthediagnosisofbreastcancer,butthespecificityisrelativelylower,theoverlapbetweenbenignandmalignantlesionsperGformance;Separateapplication1H-MRSspecificityishigher,butthesensitivityisrelativelylower;Thejointapplicationcanimprovethediagnosticsensitivity,specificKietyyawnodrdasccuracy.MagneticResonanceImaging(MRI)DynamicContrast-Enhanced(DCE-MRI)MagneticResonanceSpectroscopy(MRS)BreastCancer中图分类号R737.9文献标识码B文章编号1008-6315(2015)10-0302-02

  • 标签:
  • 简介:【摘要】目的:探讨3.0T磁共振动态增强扫描技术在垂体微腺瘤中的应用价值。方法:病例样本均为在我院接受诊疗的垂体微腺瘤患者,共计收录50例,均收录于2019.2——2022.1期间,样本入组后均接受磁共振平扫、3.0T磁共振动态增强扫描,并统计两种检查方式的检出率,分析3.0T磁共振动态增强扫描技术的影像学表现,来探讨3.0T磁共振动态增强扫描技术在垂体微腺瘤中的应用价值。结果:针对50例垂体微腺瘤患者开展磁共振平扫、3.0T磁共振动态增强扫描两种诊断方案,结果显示采用磁共振平扫进行检查时共计检出阳性33例,该诊断方式的检出率为66.00%;采用3.0T磁共振动态增强扫描进行检查时,检出阳性47例,该诊断方式的检出率为94.00%;3.0T磁共振动态增强扫描的检出率更高,P<0.05。结论:垂体微腺瘤诊断中,3.0T磁共振动态增强扫描技术具有较高的阳性检出率和明显的影像学表现特征。

  • 标签: 垂体微腺瘤 3.0T磁共振动态增强扫描技术 阳性检出率 诊断价值
  • 简介:【摘要】目的:研究分析3.0T磁共振ASL技术在缺血性脑血管疾病中的应用。方法:选取2020年5月-2021年5月我院收治的缺血性脑血管患者80例作为研究目标,按照抽签法分为常规组和研究组,各40例。常规组采用常规磁共振技术诊断,研究组采用3.0T磁共振ASL技术技术诊断,以病理结果为最终参考,对比两组患者诊断准确率。结果:研究组采用3.0T磁共振ASL技术诊断准确率明显高于常规组采用常规磁共振技术诊断,组间数据差异比较明显,(P<0.05)存在统计学意义。结论:对缺血性脑血管疾病患者,在临床中应用3D-ASL技术诊断准确率高,简单方便且无创伤,值得临床推广及应用。

  • 标签: 3.0T磁共振 ASL技术 缺血性脑血管疾病 应用效果
  • 简介:【摘要】目的 探究3.0T磁共振WB-DWI对胃癌淋巴结转移的应用。方法 对2020年5月至2023年12月期间在本院接受治疗的33例胃癌行WB-DWI检查,得到MIP图像、黑白反转图像(类“PET”图像)及伪彩色图像。本研究以淋巴结病理或临床试验性治疗复查确诊病灶为标准,探讨WB-DWI对淋巴结转移准确率、敏感度、特异性。结果33例患者均获得图像质量良好WB-DWI图像,发现淋巴结转移20例,阳性60.6%,不同部位正常淋巴结及良性淋巴结ADC值均明显高于转移淋巴结 (P<0.05),发现淋巴结转移灶的准确率为92.6%。结论3.0T 磁共振WB-DWI可清晰显示胃癌原发灶及淋巴结转移灶,对胃癌术前TNM分期及术后随访和辅助诊断具有重要价值,对胃癌淋巴结转移具有较高的准确率、敏感度、特异度,可以作为临床诊断的有效辅助手段。

  • 标签: 3.0 T磁共振 WB-DWI 胃癌淋巴结转移 检出率 准确性
  • 简介:【摘要】目的:探究针对脑血管疾病的临床诊断,核磁共振血管成像在其中的具体应用价值。方法:摘选2019-2020年来我院确诊并接受治疗的100例脑血管疾病患者,随机均分为观察组与对照组,观察组患者接受核磁共振血管成像技术检查,对照组患者接受多层螺旋CT血管成像技术检查,对两组患者的诊断精确性进行比较分析。结果:结果显示,观察组患者接受核磁共振血管成像技术检查的诊断精确性高于对照组患者接受多层螺旋CT血管成像技术检查的精确性,组间差异显著存在统计学价值(P

  • 标签: 核磁共振血管成像 脑血管疾病 临床诊断
  • 简介:摘要目的分析和总结提高急救空车途中再次出车率的方法。方法此文将随机抽取的2016年6月至2016年9月本医院100辆急救空车途中再次出车状况归入质量改进前的资料,将随机抽取的2016年12月至2017年8月本医院40辆急救空车途中再次出车状况归入质量改进后的资料,调查和统计实施质量改进前后的急救空车途中再次出车率、进步幅度、目标达成率。结果实施质量改进后的急救空车途中再次出车率高于实施质量改进前P<0.05,进步幅度为50.86%,目标达成率为113.46%。结论开展质量改进能够明显提高急救空车途中再次出车率,减少急救空车返回情况。

  • 标签: 急救车 空车 再次出车
  • 简介:【摘要】目的:分析和总结提高急救空车途中再次出车率的方法 。方法:此文将随机抽取的 2016年 6月至 2016年 9月本医院 100 辆 急救空车途中再次出车状况归入质量改进前的资料,将随机抽取的 2016 年 12 月至 2017 年 8 月本医院 40 辆 急救空车途中再次出车状况归入质量改进后的资料,调查和统计实施质量改进前后的急救空车途中再次出车率、进步幅度、目标达成率 。结果:实施质量改进后的急救空车途中再次出车率 高于实施质量改进前 P<0.05, 进步幅度为 50.86%,目标达成率为 113.46%。结论:开展质量改进能够明显提高急救空车途中再次出车率,减少急救空车返回情况 。

  • 标签: 急救车 空车 再次出车
  • 简介:在采血过程中,因精神因素、空腹献血、过度疲劳、环境因素等可引起个别献血者在献血过程中或献血后发生不良反应,影响献血者的热情。为减少献血不良反应,建立一支安全、固定的献血队伍,保证临床供血,应该为献血者创造舒适的献血环境。为此,笔者进行了在温度相当的条件下,献血车内、采血室内(包括采血屋)献血反应的统计分析,现报告如下。

  • 标签: 无偿献血 献血反应
  • 简介:摘要 :目的:分析 3.0T磁共振多 B值 DWI在前列腺疾病诊断中的临床应用。方法:对我院 2015年 12月至 2016年 12月一年间就诊的 33例前列腺增生和前列腺癌患者,使用 3.0T磁共振多 B值 DWI进行分析。结果:前列腺癌区的表观弥散系数和正常周围带以及移动带相比数值明显偏低 (P<0.05)。结论: 3.0T磁共振多 B值 DWI在前列腺疾病诊断中的临床应用具有良好的诊断效果。

  • 标签: 扩散加权成像 前列腺癌 前列腺增生 3.0T磁共振
  • 简介:  【摘要】 目的:分析 3.0T磁共振扩散加权成像( DWI)在乳腺良恶性病变鉴别诊断中的应用价值。方法:选取 2018年 1月 1日 -2019年 1月 1日笔者所在医院收诊的乳腺癌患者 35例作为恶性病变组,乳腺良性病变患者 30例作为良性病变组,正常乳腺者 30例作为正常组,均进行 3.0T DWI检查,对比三组的检查结果。结果:三组的不同 b值的平均 ADC值比较,差异均有统计学意义( P<0.05)。三组同一 b值的平均 ADC值比较,差异均有统计学意义( P<0.05)。恶性病变组 ADC值≤ 0.97 mm2/s 29例, >0.9 7mm2/s 6例,良性病变组 ADC值≤ 0.97 mm2/s 3例, >0.97 mm2/s 27例,恶性病变组 ADC值整体低于良性病变组,差异有统计学意义( P<0.05)。 b值为 1200 s/mm2时,敏感性、特异性、准确性更高,差异有统计学意义( P<0.05), b值为 1200 s/mm2时更具有应用价值。结论: 3.0T磁共振扩散加权成像在乳腺良恶性病变鉴别中具有较高的准确性、特异度与敏感性,是一种可行性较高的鉴别诊断方法。    【关键词】 3.0T磁共振扩散加权成像; 乳腺良恶性病变; 鉴别诊断; 价值    [Abstract] Objective: to analyze the value of 3.0T diffusion weighted imaging (DWI) in the differential diagnosis of breast benign and malignant lesions. Methods: from January 1, 2018 to January 1, 2019, 35 patients with breast cancer, 30 patients with benign breast disease and 30 patients with normal breast disease were selected as the malignant disease group, 30 patients with benign breast disease as the benign disease group and 30 patients with normal breast as the normal group, all of them were examined with 3.0T DWI, and the results of the three groups were compared. Results: there was significant difference in ADC between the three groups (P < 0.05). There was significant difference in the average ADC value of the same b value among the three groups (P < 0.05). There were 29 cases with ADC value ≤ 0.97 mm2 / s, 6 cases with ADC value > 0.97 mm2 / s, 3 cases with ADC value ≤ 0.97 mm2 / s and 27 cases with ADC value > 0.97 mm2 / s in the malignant group, and the ADC value in the malignant group was lower than that in the benign group, the difference was statistically significant (P < 0.05). When the b value is 1200 s / mm2, the sensitivity, specificity and accuracy are higher, and the difference is statistically significant (P < 0.05). When the b value is 1200 s / mm2, it is more applicable. Conclusion: 3.0T MR diffusion weighted imaging has high accuracy, specificity and sensitivity in the differential diagnosis of breast benign and malignant lesions, which is a feasible differential diagnosis method.

  • 标签:
  • 简介:摘要:目的:分析3.0T动态增强MRI联合CT扫描在良恶性骨肿瘤诊断中的应用价值。方法:本次研究的开始时间为2021年10月,结束时间为2022年12月,选取该期间到我院接受诊疗的良恶性骨肿瘤患者作为研究对象,共计60例,对所有患者均实施3.0T动态增强MRI扫描、CT扫描等,分析单独应用CT扫描和联合3.0T动态增强MRI措施的诊断效果。结果:CT扫描对良性骨肿瘤及恶性骨肿瘤患者的准确率均低于联合诊断,差异存在统计学意义(P<0.05)。结论:3.0T动态增强MRI联合CT扫描在良恶性骨肿瘤诊断中的准确率极高,值得临床推广应用。

  • 标签: 3.0T动态增强MRI CT扫描 良恶性肿瘤 骨肿瘤 应用价值
  • 简介:目的:探讨3.0T磁共振动态增强扫描(DCE-MRI)与氢质子波谱(1H-MRS)成像在乳腺癌定性诊断中的临床应用价值。方法收集我院经手术后病理或穿刺活检病理证实的乳腺肿瘤患者78例,共计82个肿瘤作为研究组,其中乳腺癌54个,良性肿瘤28个。全部病例均于术前行磁共振动态增强后1H-MRS检查,回顾性分析本组病例的DCE-MRI及1H-MRS表现,并将MRI诊断结果与病理结果进行对比分析。统计学处理采用χ2检验等。结果DCE-MRI检查单独诊断乳腺癌的敏感性为87%,特异性为71%,准确性为82%,阳性预测值为86%,阴性预测值为74%。1H-MRS检查单独诊断乳腺癌的敏感性为91%,特异性为86%,准确性为89%,阳性预测值为92%,阴性预测值为83%。DCE-MRI联合1H-MRS诊断乳腺癌的敏感性为98%,特异性为82%,准确性为93%。结论磁共振波谱与动态增强扫描单独诊断乳腺癌的敏感性及准确率较低,二者联合应用可明显提高其敏感性和诊断准确率,对乳腺癌的术前定性诊断有重要应用价值。

  • 标签: 磁共振成像 磁共振波谱学 乳腺肿瘤
  • 简介:【摘要】目的:分析在前列腺癌患者的临床诊断中应用3.0T磁共振波谱成像(magnetic resonance spectroscopy,MRS)的效果。方法:研究时间从2019年6月至2020年6月,研究对象为疑似前列腺癌患者,在我院收治的患者中纳入80例作为研究样本,所有患者均需要接受3.0T磁共振MRS检查,以病理诊断结果作为金标准,分析MRS检查对前列腺癌患者的诊断特异度、灵敏度以及准确度。结果:经MRI检出前列腺癌患者有72例,与病理诊断结果符合68例,特异度、灵敏度以及准确度与病理检测的对比差异无意义(P>0.05)。结论:在前列腺癌患者的临床诊断中应用3.0磁共振波谱成像检查的效果显著,诊断价值较高,值得推广。

  • 标签: 3.0T磁共振波谱成像 前列腺癌 诊断价值
  • 简介:摘要:目的:探究3.0T磁共振多种功能成像技术在前列腺癌诊断中的应用价值。方法:入组前列腺癌患者30例,对其临床资料展开回顾性分析,均进行磁共振成像(MRI)常规扫描、弥散加权成像(DWI)、波谱成像(MRS)扫描。对常规MRI扫描结果进行分析,对不同前列腺组织及其周围组织的磁共振MRS与DWI结果进行对照。磁共振DWI扫描期间,依照表观扩散系数(ADC)测量其ADC值;磁共振MRS扫描期间,入选3个体内素感兴趣,对胆碱(Cho)、肌酸(Cre)、枸橼酸盐(Cit)波峰峰值进行计算,记录(Cho+Cre)/Cit。结果:入组前列腺患者30例,共有60个前列腺侧叶,扫描诊断出前列腺癌36个侧叶。DWI扫描前列腺癌患者病灶,ADC值为(0.69±0.05)*10-3mm2/s,较周围带(1.99±0.35)*10-3mm2/s与移行带(1.53±0.23)*10-3mm2/s更低(P<0.05);MRS扫描前列腺癌患者,病灶(Cho+Cre)/Cit值为(1.69±0.43),较周围带(0.55±0.08)与移行带(0.77±0.23)更高(P<0.05)。结论:针对前列腺癌的临床诊断,以3.0T磁共振多种成像技术实施检查,以DWI扫描获取ADC值,以MRS获取(Cho+Cre)/Cit值,均为有效的临床诊断依据,推广意义深远。

  • 标签: 3.0T磁共振 多种功能成像技术 前列腺癌 诊断
  • 简介:摘要:目的 探讨磁共振扩散加权成像( DWI)在评估 宫颈癌新辅助化疗( NACT)疗效中的应用价值。方法 选取 2015 年 8月 -2017 年 8 月在我院就诊的宫颈癌患者行新辅助化疗治疗,观察疗效和 ADC值变化 ,并分析化疗前后宫颈癌组织的 ADC值变化。结果 56例病人, 44例化疗有效( 3例完全反应, 41例部分反应), 12例无效( 2例疾病进展, 10例疾病稳定),化疗效率 78.57%; 随 b值增病变组织图像更加清晰,对应的 ADC值呈减小趋势; 结论 DWI可鉴别宫颈癌和正常宫颈,有助于宫颈癌的诊断和疗效的预测。

  • 标签: 3.0T磁共振扩散加权成像 子宫颈癌 新辅助化疗
  • 简介:摘要:目的:分析3.0T磁共振动脉自旋标记(ASL)联合弥散加权成像(DWI)技术在急性缺血性脑卒中患者中的临床应用价值。方法:选取2021年11月-2022年11月,我院收治的64例急性缺血性脑卒中患者,将其当作本次实验的对象,所有患者接受Ge3.0T磁共振ASL及DWI成像诊断,将诊断结果与同期64例健康体检者的检查结果进行对比,观察3.0T磁共振ASL及DWI成像在检测中的应用价值。结果:经诊断后,右侧大脑半球急性缺血性脑卒中患者的右侧脑血流量绝对值显著低于左侧,且两侧脑血流量绝对值低于健康对照组;左侧大脑半球急性缺血性脑卒中患者的两侧脑血流量绝对值均低于健康对照组,差异有统计学意义(P<0.05)。结论:3.0T磁共振ASL联合DWI成像能够清楚显示急性缺血性脑卒中患者局部脑组织缺血梗死病灶的血流动力学改变,再结合脑血流量数值,便可以更为准确、客观的反映出患者脑组织缺血梗死灌注情况,进而为临床诊断疾病带来了更可靠的依据。

  • 标签: 3.0T 磁共振ASL DWI成像 急性缺血性脑卒中 应用价值
  • 简介:[摘要]目的 研究护理干预在高场强3.0T磁共振子宫输卵管造影检查应用中的效果。方法 选入2023年1月—12月在本院进行高场强3.0T磁共振子宫输卵管造影检查的患者40例,将使用护理干预的20例作为护理组,将使用常规干预的20例作为常规组,对比两组不良反应、依从率。结果 不良反应发生率护理组比常规组低,P<0.05;总依从率护理组比常规组高,P<0.05。结论 在高场强3.0T磁共振子宫输卵管造影检查中应用护理干预效果理想,能够减少不良反应,提高患者依从性,降低不适感。

  • 标签: [] 护理干预 高场强3.0T磁共振 子宫输卵管造影检查
  • 简介:摘要目的评价自行设计医用多功能治疗的临床应用效果。方法自行研制医用多功能,随机选取9个科室的护理人员,通过自制调查问卷对护理人员进行工作满意度调查,对2017年1~12月使用普通治疗与2018年1~12月使用的医用多功能满意情况进行比较。结果两组护理人员在工作满意度方面比较差异具有统计学意义(P<0.05)。结论医用多功能设计科学合理,自由装卸、收纳清洁,降低了院内感染发生率;同时提高了护士工作效率和满意度。

  • 标签: 多功能车 研制 临床应用