学科分类
/ 1
2 个结果
  • 简介:AIM:Tomeasurecentralcornealthickness(CCT)andpre-cornealtearfilmthicknessusingtheGalileidualScheimpfluganalyzer(GSA)inNewZealandWhiterabbits.METHODS:TennormalNewZealandWhiterabbits(20eyes)wereincludedinthisstudy.Withtheassistanceof0.1%fluorescein,thepre-cornealtearfilmcanbewellvisualized.BotheyesofeachrabbitwerescannedoncewiththeGSApre-andpost-instillationof1μL0.1%fluorescein.ThedifferencebetweenthetwomeasurementsofCCT(4-mmdiameter)wasrecordedasthepachymetricvaluesofthecentraltearfilm.RESULTS:TheCCTofpre-andpost-instillationwas388.8±9.5μmand407.0±10.5μm,respectively.Afterapairedt-testanalysis,thecentralpre-cornealtearfilmthicknessof4mmdiameterwas18.2±5.31μmwitha95%confidenceintervalof(15.7,20.6)μm(P<0.001).CONCLUSION:GSAcanbeusedtomeasureCCTandanalyzecentraltearfilmthicknessofrabbitswiththehelpoffluorescein.

  • 标签: TEAR film SCHEIMPFLUG rabbits central CORNEAL
  • 简介:AIM:Toevaluatetheaccuracyofsphericalequivalent(SE)estimatesofadouble-passsystemandtocompareitwithretinoscopy,subjectiverefractionandatablemountedautorefractor.METHODS:Non-cycloplegicrefractionwasperformedon125eyesof65healthyadults(age23.5±3.0years)fromOctober2010toJanuary2011usingretinoscopy,subjectiverefraction,autorefraction(AutokeratorefractometerTOPCONKR-8100,Japan)andadoublepasssystem(OpticalQualityAnalysisSystem,OQAS,VisiometricsS.L.,Spain).Nineconsecutivemeasurementswiththedouble-passsystemwereperformedonasubgroupof22eyestoassessrepeatability.ToevaluatethetruenessoftheOQASinstrument,theSElaboratorybiasbetweenthedoublepasssystemandtheothertechniqueswascalculated.RESULTS:TheSEmeancoefficientofrepeatabilityobtainedwas0.22D.SignificantcorrelationscouldbeestablishedbetweentheOQASandtheSEobtainedwithretinoscopy(r=0.956,P<0.001),subjectiverefraction(r=0.955,P<0.001)andautorefraction(r=0.957,P<0.001).ThedifferencesinSEbetweenthedouble-passsystemandtheothertechniquesweresignificant(P<0.001),butlackedclinicalrelevanceexceptforretinoscopy;Retinoscopygavemorehyperopicvaluesthanthedouble-passsystem-0.51±0.50Daswellasthesubjectiverefraction-0.23±0.50D;Moremyopicvalueswereachievedbymeansofautorefraction0.24±0.49D.CONCLUSION:Thedouble-passsystemprovidesaccurateandreliableestimatesoftheSEthatcanbeusedforclinicalstudies.Thistechniquecandeterminethecorrectfocuspositiontoassesstheocularopticalquality.However,ithasarelativelysmallmeasuringrangeincomparisonwithautorefractors(-8.00to+5.00D),andrequirespriorinformationontherefractivestateofthepatient.

  • 标签: DOUBLE-PASS system optical quality RETINOSCOPY autorefraction